Kaizhiquan's Diesel Engine Fire-Fighting Pump Set is engineered for reliable emergency fire protection when main electric power fails. Manufactured directly at our 22,000 m² Wenzhou plant, every unit is EU CE and China CCCF certified and undergoes full hydraulic and load testing before shipment—with factory test photos and videos shared prior to delivery.
· Automatic alarm and shutdown conditions: loss of speed signal, over/under-speed, low oil pressure, start/stop failure, open/short circuits in sensors (oil pressure, water temperature, etc.), low water pump pressure, etc.
· Pre-alarm conditions: over/under-speed, low oil pressure, high coolant temperature, low ambient temperature, low fuel level, high/low battery voltage, uncalibrated speed signal, low water pump pressure, etc.
Status Mode
· Diesel engine operating status display: Standby, Power-on, Fuel supply, Cranking, Start delay, Idle delay, Normal operation, Cooling shutdown, Emergency shutdown.
· Manual/Automatic/Remote control: Supports manual, automatic, and remote control of water pump start/stop; control modes are switchable.
Parameter Settings
· Diesel engine parameter measurement and display: Engine speed, running time, fuel level, battery voltage, coolant temperature, oil pressure.
· Configurable diesel engine control timings: Start delay, pre-heating or pre-lubrication time, cranking cutoff time, ramp-up time, cooling shutdown time.
Detailed Description
Product Description
The XBC series diesel-driven fire pump unit is a stationary fire-fighting system developed and manufactured by our company in accordance with the national standard GB6245-2006 (Fire Pumps) and with reference to the NFPA 20 standard of the National Fire Protection Association. Designed for situations where a fire occurs and the electric fire pump fails to operate due to a power outage, this unit automatically activates to ensure effective fire suppression and safeguard lives and property. The system features various automatic control functions to guarantee reliable long-term standby readiness and immediate deployment for fire-fighting operations. The unit pairs a high-quality domestic or imported diesel engine with a fire-fighting water pump. It is characterized by rapid starting, reliable priming, ample power reserve, stable operation, a high degree of standardization, and a wide range of pressure and flow capabilities, making it a dependable piece of fire-fighting equipment. This pump unit is also suitable for other emergency backup applications, such as flood control, drainage, and agricultural irrigation.
Performance Parameters
Model
Flow rate (L/s)
Pressure (MPa)
Power (kW)
Rated speed (r/min)
XBC5.5/20G-W
20
0.55
29
2900
XBC10.5/20G-W
20
1.05
72
2900
XBC10.0/25G-W
25
1
72
2900
XBC8.0/30G-W
30
0.8
63
2900
XBC10.0/30G-W
30
1
100
2900
XBC5.2/40G-W
40
0.52
42
2900
XBC7.0/40G-W
40
0.7
76
2900
XBC8.0/40G-W
40
0.8
72
2900
XBC10.0/40G-W
40
1
100
2900
XBC5.7/50G-W
50
0.57
72
2900
XBC6.5/50G-W
50
0.65
72
2900
XBC7.8/50G-W
50
0.78
100
2900
XBC9.0/50G-W
50
0.9
117
2900
XBC6.2/50G-W
60
0.62
72
2900
XBC7.2/50G-W
60
0.72
100
2900
Key Product Advantages
Automatic Emergency Startup: Automatically starts when receiving a fire alarm signal or when main electric power fails, ensuring uninterrupted fire water supply.
Three Starting Modes: Supports automatic start, manual local start, and emergency mechanical start, with built-in automatic battery charging.
Flexible Pump Configurations: Available with end-suction, double-suction split-case, or multistage centrifugal fire pumps—supplied standalone or as a complete skid-mounted package (Diesel + Electric + Jockey Pump + Automatic Control Cabinet).
Factory-Direct Supply & Fast Delivery: Standard sets ship in 7–10 working days (custom packages in 15–20 days), backed by a 12-month warranty and lifetime technical support.
Material Construction & Configuration Options
Pump Casing: Cast Iron / Ductile Iron / Stainless Steel (SS304 / SS316)
Shaft Seal: Heavy-duty Mechanical Seal or Gland Packing
Control Cabinet: Automatic & manual operation with oil pressure, water temperature, speed, and fault alarm monitoring
Power & Cooling: Air-cooled or radiator water-cooled diesel engine; auxiliary systems available in 50Hz or 60Hz
Typical Applications
Commercial high-rise buildings, hotels, hospitals, and shopping malls
Industrial factories, logistics warehouses, and oil & gas / petrochemical facilities
Municipal fire hydrant networks, airports, and ports
Frequently Asked Questions (FAQ)
Q: Can you supply a complete Diesel + Electric + Jockey fire pump skid? Yes. We supply complete pre-assembled fire pump packages mounted on a common base frame with automatic control cabinets, valves, and pressure gauges.
Q: Do you test the diesel fire pump set before shipping? Yes. Every unit runs through full-load performance and pressure testing at our factory, and we send test photos and videos before balance payment and shipment.
Q: What trade terms and delivery time do you offer? We offer EXW and FOB Shanghai terms. Standard units ship within 7–10 working days, and customized packages take 15–20 days.
Q: How do I get a quick quotation? Send us your required Flow Rate (m³/h or GPM), Head (m or Bar), and System Type via the inquiry form below or click our WhatsApp button for a direct factory quote.
Product Structure Diagram
Product Application Areas
FAQs:
1
Why use a diesel fire pump instead of an electric fire pump?
Diesel fire pumps provide an independent power source and can continue working during electrical failures, making them ideal as emergency backup fire protection equipment.
2
Can the XBC diesel fire pump start automatically?
Yes. The automatic control system can receive fire signals or pressure drop signals and start the diesel engine automatically.
3
What information is needed to select the correct model?
Customers should provide:
Required flow rate (L/s or m³/h);
Required pressure/head (MPa or m);
Building/project type;
Power supply condition;
Installation environment.
4
Can you provide complete fire pump systems?
Yes. We can provide complete solutions including:
Diesel fire pump;
Electric fire pump;
Jockey pump;
Control cabinet;
Accessories and installation guidance.